1. Overall Performance
Equipment TypeFully Automatic, discrete, STAT priority
Throughput (theoretical max)300T/H for photometry tests only
Test PrincipleColorimetry, turbidimetry, ISE
Analysis MethodEnd-point, kinetics, fixed time, etc.
Simultaneous analysis item66 colorimetric items and 3 ISE items (K, Na, Cl optional)
2. Sample Unit
Sample Position115 sample positions, including 50 routine sample positions, 20 STAT positions, 34 calibrations positions, 8 QC positions, 3 detergent positions
Sample Cuvettes SpecificationStandard cup, original blood tube, multi-specification tube available
Sample Barcode12 of 5, code 128, code 39, UPC/EAN, code 93
Sample Volume2µ- 350µL, 0.1µL stepping
Sample TechnologyLiquid level detection and collision detection
Sample ProbeAutomatic warm water cleaning
Carrying RateCarrying rate ≤0.1%
Automatic Sample Dilution3-170 times
3. Reagent Unit
Reagent Probe1, with the function of liquid level detection and collision detection
Reagent Volume20µL - 350µL, 1µL stepping
Reagent Positionsingle reagent disk, maximum 67 positions available, continuous 5-150C cooling within, 24 hours, loading 70 ml, 20 ml or 100 ml standard reagent kit
Reagent Barcodecode 128
Reagent Probe Carrying RateAutomatic warm water cleaning. Carrying rate ≤0.1%
4. Reaction Unit
Reaction Cuvette120 optical plastic cup, optical diameter is 6 mm
Total Volume of Reaction Liquid150µL - 450µL
Reaction Temperature370C, ±0.10C
Reaction Disk ConstantCirculating water
Temperature Mixer1, after inputting reagent, blending immediately
Wastewater Treatmenttwo diffluence for high and low concentration waste water. With the function of concentrated waste liquid level alarming
5. Optical System
Light Source20W / 12V halogen lamps
MonochromatorGrating photometry
Photoelectron roadRear spectrophotometry
Wavelength340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800nm
DetectorPhotodiode LED array
OD Linear range0-3.3 Abs
6. Calibration and QC
Calibration1 point linear method, 2 point linear method, multiple point linear method, non-linear method
Calibrating TrackingAutomatic description calibration K-Value trends
QC MethodsReal-time QC, individual QC and monthly QC
Out of Control ProcessingAlarming for out of control sample, record lost control reason
7. Operating System
PC Operating SystemWindows XP
Analysis Control SoftwareEnglish version graphical operating software
Main Function of SoftwareAutomatic, automatic barcode scanning, item compounding test, reagent info management, serum index, whole reaction process monitoring, dirty cup memory evading, prevent cross-contatmination procedure, patient information memory and association input, automatic report audit, data multiple parameter query, report format statistic and printing, reference range classification, alarming information classification, user operating right classification, automatic dormancy and wake, real-time online help, alarm for daily, weekly and monthly maitnenance
Report PrintingReport formats support the user-defined mode, QC and state information, etc
PC configurationCPU ≥ 2.2GHz (dual-core processor); Memory ≥ 1G; Harddisk > 160G; 17 inch LCD display; Stylus, inkjet or laser printer (optional)
System connectionTCP/IP network connection, standard RS-232C
8. Others
Volume1060 mm x 790 mm x 1150 mm
Weight230 Kg
Power SupplyVoltage AC 220V±22V, 50/60 Hz, power 1.5kVA
Catalog No. Product Packaging
CS-300B CS-300B Automatic Chemistry Analyzer Unit
CS-300B Auto-Chemistry Analyzer is a small sized floor top analyzer. It is the ideal instrument for consolidating test in low workload small or medium size laboratories. It offers performance of up to 66 test items simultaneously and up to 300 tests per hour.

service@setia-medika.co.id

support@setia-medika.co.id

0812 – 2000 – 6006

Related Information

Events|Blog|Locations|News|e-Catalogue
© Copyright 2016 PT.Setia Medika.
All rights reserved.

CS-300B Automatic Chemistry Analyzer

CS-300B Automatic Chemistry Analyzer
1. Overall Performance
Equipment TypeFully Automatic, discrete, STAT priority
Throughput (theoretical max)300T/H for photometry tests only
Test PrincipleColorimetry, turbidimetry, ISE
Analysis MethodEnd-point, kinetics, fixed time, etc.
Simultaneous analysis item66 colorimetric items and 3 ISE items (K, Na, Cl optional)
2. Sample Unit
Sample Position115 sample positions, including 50 routine sample positions, 20 STAT positions, 34 calibrations positions, 8 QC positions, 3 detergent positions
Sample Cuvettes SpecificationStandard cup, original blood tube, multi-specification tube available
Sample Barcode12 of 5, code 128, code 39, UPC/EAN, code 93
Sample Volume2µ- 350µL, 0.1µL stepping
Sample TechnologyLiquid level detection and collision detection
Sample ProbeAutomatic warm water cleaning
Carrying RateCarrying rate ≤0.1%
Automatic Sample Dilution3-170 times
3. Reagent Unit
Reagent Probe1, with the function of liquid level detection and collision detection
Reagent Volume20µL - 350µL, 1µL stepping
Reagent Positionsingle reagent disk, maximum 67 positions available, continuous 5-150C cooling within, 24 hours, loading 70 ml, 20 ml or 100 ml standard reagent kit
Reagent Barcodecode 128
Reagent Probe Carrying RateAutomatic warm water cleaning. Carrying rate ≤0.1%
4. Reaction Unit
Reaction Cuvette120 optical plastic cup, optical diameter is 6 mm
Total Volume of Reaction Liquid150µL - 450µL
Reaction Temperature370C, ±0.10C
Reaction Disk ConstantCirculating water
Temperature Mixer1, after inputting reagent, blending immediately
Wastewater Treatmenttwo diffluence for high and low concentration waste water. With the function of concentrated waste liquid level alarming
5. Optical System
Light Source20W / 12V halogen lamps
MonochromatorGrating photometry
Photoelectron roadRear spectrophotometry
Wavelength340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800nm
DetectorPhotodiode LED array
OD Linear range0-3.3 Abs
6. Calibration and QC
Calibration1 point linear method, 2 point linear method, multiple point linear method, non-linear method
Calibrating TrackingAutomatic description calibration K-Value trends
QC MethodsReal-time QC, individual QC and monthly QC
Out of Control ProcessingAlarming for out of control sample, record lost control reason
7. Operating System
PC Operating SystemWindows XP
Analysis Control SoftwareEnglish version graphical operating software
Main Function of SoftwareAutomatic, automatic barcode scanning, item compounding test, reagent info management, serum index, whole reaction process monitoring, dirty cup memory evading, prevent cross-contatmination procedure, patient information memory and association input, automatic report audit, data multiple parameter query, report format statistic and printing, reference range classification, alarming information classification, user operating right classification, automatic dormancy and wake, real-time online help, alarm for daily, weekly and monthly maitnenance
Report PrintingReport formats support the user-defined mode, QC and state information, etc
PC configurationCPU ≥ 2.2GHz (dual-core processor); Memory ≥ 1G; Harddisk > 160G; 17 inch LCD display; Stylus, inkjet or laser printer (optional)
System connectionTCP/IP network connection, standard RS-232C
8. Others
Volume1060 mm x 790 mm x 1150 mm
Weight230 Kg
Power SupplyVoltage AC 220V±22V, 50/60 Hz, power 1.5kVA