DL96II

DL96II
Testing Principles Identification: Colorimetry
Susceptibility testing : Turbidimetry
Throughput 60-120 cards per hour
Optimal configuration Automated sampling device, sampling 60-80 cards per hour
Printer External printer
Interface Internal PC, support LIS/HIS, WHONET
Working Environment Environmental temperature : 50C-400C
Relative humidity : 10%-90%
Atmospheric pressure 76kPa - 106kPa
Power supply AC220V±22V, 50Hz±1Hz
Dimension & Weight 700mm x 493mm x 465mm ; 31.2 kg
Instrument
DL-96II Microbial Identification and Antimicrobial Susceptibility Testing System (ID/AST) Unit

Microbial Identification & Antimicrobial Susceptibility Testing System

DL-96II is used to identify isolated bacteria and fungus and determine its MIC to different antibiotics. DL-96II contains a set of detection device and embedded control device. DL-96II detects and analyzes the specimen in reagent plate by colorimetry and nephelometry, and automatically generate the results of bacterial species.

Feature:

  1. DL-96II database is updated with the latest CLSI.
  2. Integrated with reader and Analyzer (inner computer)
  3. LIS/HIS and WHONET support
  4. English interface. Easy to understand and operate.

DL-96II brochure
Description: http://www.medicaldl.com/en/uf/20140807143442404240.JPG Brosur DL-96_4b



service@setia-medika.co.id

support@setia-medika.co.id

0812 – 2000 – 6006

Related Information

DL-96II/DL-96II Microbial ID & AST system VS Biomerieux VITEK2 Compact comparison report in The Armed Police General Hospital.pdf
Events|Blog|Locations|News|e-Catalogue
© Copyright 2016 PT.Setia Medika.
All rights reserved.

DL96II

DL96II
Testing Principles Identification: Colorimetry
Susceptibility testing : Turbidimetry
Throughput 60-120 cards per hour
Optimal configuration Automated sampling device, sampling 60-80 cards per hour
Printer External printer
Interface Internal PC, support LIS/HIS, WHONET
Working Environment Environmental temperature : 50C-400C
Relative humidity : 10%-90%
Atmospheric pressure 76kPa - 106kPa
Power supply AC220V±22V, 50Hz±1Hz
Dimension & Weight 700mm x 493mm x 465mm ; 31.2 kg
Instrument
DL-96II Microbial Identification and Antimicrobial Susceptibility Testing System (ID/AST) Unit

Microbial Identification & Antimicrobial Susceptibility Testing System

DL-96II is used to identify isolated bacteria and fungus and determine its MIC to different antibiotics. DL-96II contains a set of detection device and embedded control device. DL-96II detects and analyzes the specimen in reagent plate by colorimetry and nephelometry, and automatically generate the results of bacterial species.

Feature:

  1. DL-96II database is updated with the latest CLSI.
  2. Integrated with reader and Analyzer (inner computer)
  3. LIS/HIS and WHONET support
  4. English interface. Easy to understand and operate.

DL-96II brochure
Description: http://www.medicaldl.com/en/uf/20140807143442404240.JPG Brosur DL-96_4b



service@setia-medika.co.id

support@setia-medika.co.id

0812 – 2000 – 6006

Related Information

DL-96II/DL-96II Microbial ID & AST system VS Biomerieux VITEK2 Compact comparison report in The Armed Police General Hospital.pdf